    2.   PACKAGES OF A SOLID FUEL BOILER, SUPPLEMENTARY HEATERS, TEMPERATURE CONTROLS AND SOLAR DEVICES

    For packages of a solid fuel boiler, supplementary heaters, temperature controls and solar devices, the technical documentation referred to in Article 3(3)(e) shall include:
    (a) the name and address of the supplier;
    (b) a description of the model comprising the package of a solid fuel boiler, supplementary heaters, temperatures control and solar devices sufficient for its unambiguous identification;
    (c) where appropriate, the references of the harmonised standards applied;
    (d) where appropriate, the other technical standards and specifications used;
    (e) the name and signature of the person empowered to bind the supplier;
    (f) technical parameters:
    (1) the energy efficiency index, rounded to the nearest integer;
    (2) the technical parameters set out in point 1 of this Annex and, where appropriate, the technical parameters set out in point 1 of Annex V of Commission Delegated Regulation (EU) No 811/2013;
    (3) the technical parameters set out in points 3 and 4 of Annex V of Commission Delegated Regulation (EU) No 811/2013;
    (g) any specific precautions that must be taken when the package of a solid fuel boiler, supplementary heaters, temperature controls and solar devices is assembled, installed or maintained.
    (1)  Directive 2009/125/EC of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy-related products (
    OJ L 285, 31.10.2009, p. 10
    ).
    (2)  Tank volume = 45 ×
    P
    r
    × (1 – 2,7/
    P
    r
    ) or 300 litres whichever is higher, with
    P
    r
    indicated in kW
    (3)  Tank volume = 20 ×
    P
    r
    with
    P
    r
    indicated in kW
    (4)  For the preferred fuel
    P
    n
    equals
    P
    r

    ANNEX VI

    Information to be provided in cases where end-users cannot be expected to see the product displayed, except on the internet

    1.   SOLID FUEL BOILERS

    1.1.   The information referred to in Article 4(1)(b) shall be provided in the following order:
    (a) the energy efficiency class of the model, determined in accordance with Annex II;
    (b) the rated heat output in kW, rounded to the nearest integer;
    (c) the energy efficiency index, rounded to the nearest integer and calculated in accordance with Annex IX;
    (d) in the case of solid fuel cogeneration boilers the electrical efficiency in %, rounded to the nearest integer.
    1.2.   The size and font in which the information referred in point 1.1 is printed or shown shall be legible.

    2.   PACKAGES OF A SOLID FUEL BOILER, SUPPLEMENTARY HEATERS, TEMPERATURE CONTROLS AND SOLAR DEVICES

    2.1.   The information referred to in Article 4(2)(b) shall be provided in the following order:
    (a) the energy efficiency class of the model, determined in accordance with Annex II;
    (b) the energy efficiency index, rounded to the nearest integer;
    (c) the information set out in Figure 1 and Figure 2 of Annex IV, as appropriate.
    2.2.   The size and font in which the information referred in point 2.1 is printed or shown shall be legible.

    ANNEX VII

    Information to be provided in the case of sale, hire or hire-purchase through the internet

    1.
    For the purpose of points 2 to 5 of this Annex the following definitions shall apply: